GI Earthing Electrodes(Galvanize Iron)
GI Earthing or Gel earthing system is the process of creating an alternative path for the flow of excessive/fault current safely into the ground in the presence of minimal resistance.
Our GI earthing system offers superior product life, cost effective, maintenance free as well as reduces the maintenance cost.
SI Gel offers gel earth electrodes features like superior quality, properly galvanized, variable choices, cost effective, maintenance free and global technology are highly preferred.
Gel earthing electrodes easily install with less space required compared to conventional GI earthing and yet has longer life. Earthing materials which surrounds gi earth electrode is hygroscopic and conductive that helps the longer period of effective earthing. A GI earthing material has the quality of absorbing and retaining moisture content for a very long period.
GI (Galvanized iron) Ground Electrode provides a low-impedance ground in locations of high soil resistivity. Together with SI Back fill Compound, the system dissipates lightning energy and other dangerous electrical fault currents, even in sandy or rocky soil conditions.
- High working life
- Reliability
- Require minimal maintenance
- Maintenance free
- Longevity
Low-Impedance Grounding
The SI Gel Earthing electrode is designed using high end raw materials to ensure a constant, low-impedance electrical link with the earth. They are designed in such a way that they can easily offer unbeatable performance even in adverse and varying ground conditions such as permafrost.Large surface area
GI Earthing Electrode is designed with large surface to make sure the better connection with the Earth. We have been offering them with 25/8 inch diameter.Electrolytic salts
Moisture makes electrolytic salts dissolved. After dissolving, these salts seep out of leach holes and the electrode that enhance the soil conductivity, reduce impedance and resistance.Soil augmentation
BFC is a mixture of organic soil material that optimizes the soil conductivity level around the Earthing Electrode. When the amount of BFC increases, it leads to the decrease of the overall system resistance property and increase of the system efficacy.Maintenance-Free
We have been offering maintenance free Earthing Electrode in India to offer the best value of the money to the clients. There is no need to pour extra water from time to time as it was done in conventional Earthing because it can retain the moisture.Consistency
Being a trusted GI earthing electrode manufacturer, we have been offering electrodes that continually maintains the same earth resistance value even in the adverse soil as well as climate conditions. The stability factor of these Electrodes remains constant for a longer period of time. In addition to this, the resistance property of the electrode is also least affected by unfavorable climatic conditions.Consistency
Being a trusted GI earthing electrode manufacturer, we have been offering electrodes that continually maintains the same earth resistance value even in the adverse soil as well as climate conditions. The stability factor of these Electrodes remains constant for a longer period of time. In addition to this, the resistance property of the electrode is also least affected by unfavorable climatic conditions.Adequate galvanization, Highly conductive, No corrosion, eco-friendly and a long and reliable life (Fit and Forget).
Easy Installation
Easy to install, our array of electrodes can be installed instantly and effortlessly anywhere. As it provides the best performance in almost every soil condition, you can easily install it indoors or outdoors according to your wish. It also requires less time and space to get is installed.Improved Safety
Sometimes, the harm caused by a single lightning hit or stray current becomes unaffordable. It not only damages your valuable equipment, but also human life. The SI Gel GI earthing electrode has considered as the best option in this regard. Electrodes, offered by us, are sure to reduce the risks of any valuable or human life hard more effectively than any other kind of ground rods. With the most efficient earth interface, you can easily feel safe and secure during lightning. Furthermore, our gamut of electrodes also meets or exceeds applicable design codes and safety standards to provide 100% protection to personnel, property, as well as sensitive equipment.Designed with Lightning in Mind
High-frequency passing events such as lightning forces, current surge, etc. to the surface of an object. During these events, the electrode having more surface area has low impedance. Earthing electrode in GI pipe, offered by SEIPL, is designed with four times more surface area than any other traditional ground rod. Larger surface area assists in creating the low-impedance link necessary to safely channel high-frequency lightning currents to the Earth.In addition to all above features, our wide collection of products is highly conductive.
- Lightning protection systems
- Prevention of accidents caused by static charge and stray currents.
- Protection of central communications, electronics, and AC power systems.
- Meeting grounding safety requirements for electrical substations.
- Ground fault neutralization.
- Safeguarding critical instrumentation and process control equipment.
Applications
Efficient Grounding Systems reduce the risk of electrical arcing and fires. The SI Gel Safe Earthing Electrode improves reliability for many applications, including:
Models | Electrode Diameter (MM) | Length (MM) | Internal Dia (MM) | Connection Terminal Hole Die (MM)x No. of Hole | M.O.C | Compound Filled(CCM) |
---|---|---|---|---|---|---|
SI 19/1 | 46-50 | 1000 | 22-25 | 10 X 02 | HDGI | |
SI 19/2 | 46-50 | 2000 | 22-25 | 10 X 02 | HDGI | |
SI 19/3 | 46-50 | 3000 | 22-25 | 10 X 02 | HDGI | |
SI 39/1 | 76-80 | 1000 | 37-40 | 10 X 02 | HDGI | |
SI 39/2 | 76-80 | 2000 | 37-40 | 10 X 02 | HDGI | |
SI 39/3 | 76-80 | 3000 | 37-40 | 10 X 02 | HDGI |